Hyundai Elantra: Engine Control System / Purge Control Solenoid Valve (PCSV) Description and Operation
Purge Control Solenoid Valve (PCSV) is installed on the
intake manifold and controls the evaporative purge between the canister
and the intake manifold. It is a normally closed solenoid valve and is
open when the ECM grounds the valve control line. When the passage is
open (PCSV ON), fuel vapor stored in the canister is transferred to the
intake manifold.
Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the injector connector.
3.
Measure resistance between the injector terminals 1 and 2.
4.
Check that the resistance is within t ...
Specification
ItemSpecificationCoil Resistance (?)22.0 ~ 26.0 [20°C(68°F)]
...