Inspection
1.
Connect the battery voltage and check the blower motor rotation.

2.
If the blower motor does not operate well, substitute with a known-good blower motor and check for proper operation.
3.
Replace the blower motor if it is proved that there is a problem with it.
Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the cowl side trim.
(Refer to Body - "Cowl Side Trim")
3.
To remove the crash pad under cover [RH] (A), press both sides of the locking pin and then pull it down.

4.
Disconnect the blower motor connector (A) and then remove the blower motor (B) after loosening the screws.

5.
To intall, reverse the removal procedure.
Blower Unit Repair procedures
Replacement     When prying with a flat-tip screwdriver or use a prying trim tool, wrap it with protective tape, and apply protective tape around the related parts, to prevent ...

Power Mosfet Description and Operation
Description It is installed to the DATC and adjusts the fan rpm by precisely controlling the voltage applied to the blower motor. ...

Other information:

Hyundai Elantra AD (2016-2020) Owners Manual: System Maintenance
Climate control air filter This filter is installed behind the glove box. It filters the dust or other pollutants that enter the vehicle through the heating and air conditioning system. Have the climate control air filter replaced by an authorized HYUNDAI dealer according to the maintenance ...

Hyundai Elantra AD (2016-2020) Service Manual: Radiator Repair procedures
Inspection Radiator Cap Testing 1. Remove the radiator cap, wet its seal with engine coolant, and then install it on a pressure tester. 2. Apply a pressure of 93.16 ~ 122.58 kPa (0.95 ~ 1.25 kgf/cm?, 13.51 ~ 17.78 psi). 3. Check for a drop in pressure. 4. If the pressure drops, re ...

© 2018-2025 www.helantraad.com