Hyundai Elantra: Air Conditioning System / Evaporator Temperature Sensor Description and Operation

Description
The evaporator temperature sensor will detect the evaporator core temperature and interrupt compressor relay power in order to prevent evaporator from freezing by excessive cooling. The evaporator temperature sensor has the Negative Temperature Coefficient (NTC). Electrical resistivity of NTC will increase with decreasing temperature and decrease with increasing temperature.
A/C Pressure Transducer Repair procedures
Inspection 1. Measure the pressure of high pressure line by measuring voltage output between terminal “1” and “2”. 2. Inspect the voltage value whether it is sufficient to be regular v ...

Evaporator Temperature Sensor Repair procedures
Inspection 1. Turn the ignition switch OFF. 2. Disconnect the evaporator temperature sensor connector. 3. Measure the resistance between terminal "+" and "-" of the evaporator temperature ...

Other information:

Hyundai Elantra AD (2016-2020) Service Manual: Specifications
Specifications ItemsSpecificationHoodTypeFront openine type, rear hinged, stay rod typeFront DoorConstructionFront hinged, frame door constructionRegulator systemWire drum typeLocking systemPin-fork systemRear DoorConstructionFront hinged, frame door constructionRegulator systemWire drum typeLo ...

Hyundai Elantra AD (2016-2020) Owners Manual: Fuel Filler Door
Opening the fuel filler door The fuel filler door must be opened from inside the vehicle by pulling up the fuel filler door release lever. 1. Turn the engine off. Locate the fuel filler door release lever on the floor on the left side of the driver seat. 2. Pull up on the release lever. ...