Hyundai Elantra: Airbag Module / Knee Airbag (KAB) Module Repair procedures

Hyundai Elantra AD (2016-2020) Service Manual / Restraint / Airbag Module / Knee Airbag (KAB) Module Repair procedures

Removal
1.
Disconnect the battery negative cable and wait for at least 3 minutes before beginning work.
2.
Remove the crash pad lower panel.
(Refer to Body - "Crash Pad Lower Panel")
3.
Remove the knee airbag module (A) after loosening the mounting nuts.

4.
Disconnect the knee airbag module connector (A).

Installation
1.
Remove the ignition key from the vehicle.
2.
Disconnect the battery negative cable and wait for at least three minutes.
3.
Install the knee airbag module after connect the knee airbag module connector.

Tightening torque :
Bolt : 7.8 ~ 11.8 N.m (0.8 ~ 1.2 kgf.m, 5.8 ~ 8.7 lb-ft)

4.
Install the crash pad lower panel.
5.
Reconnect the battery negative cable.
6.
After installing the knee airbag (KAB), confirm proper system operation :
A.
Turn the ignition switch ON; the SRS indicator light should be turned on for about six seconds and then go off.
Knee Airbag (KAB) Module Description and Operation
Description The Knee Airbag (KAB) is installed inside the crash pad lower panel and protects the driver in the event of a frontal crash. The SRSCM determines if and when to deploy the KAB. ...

Airbag Module Disposal Description and Operation
Airbag Disposal When you scrap a vehicle equipped with an airbag, you must deploy it first. When you deploy an airbag, you need to have a skilled mechanic do the work. The used airbag should no ...

Other information:

Hyundai Elantra AD (2016-2020) Service Manual: Variable Charge Motion Actuator (VCMA) Repair procedures
Inspection 1. Turn ignition switch OFF. 2. Disconnect the VCMA connector. 3. Check that the VCMA is not stuck by foreign material. 4. Measure resistance between motor (+) and (-) control terminals of the motor. 5. Check that the resistance is within the specification. Sp ...

Hyundai Elantra AD (2016-2020) Service Manual: A/C Pressure Transducer Repair procedures
Inspection 1. Measure the pressure of high pressure line by measuring voltage output between terminal “1” and “2”. 2. Inspect the voltage value whether it is sufficient to be regular value or not. Voltage = 0.00878835 * Pressure + 0.37081095 3. If the measured voltage value ...

© 2018-2025 www.helantraad.com